If you have been reading about detector and want a single page that covers the useful parts, this is it: definitions, context, how it is studied, and the questions that come up repeatedly.
Updated 2026-02-04. Numbers and descriptions here follow the published literature rather than marketing material.
Laboratories apply HPLC testing across pharmaceutical, food, environmental, and industrial chemistry. The method can measure active ingredients, impurities, additives, preservatives, and degradation products. Sample preparation often includes dilution, filtration, and sometimes extraction or derivatization. The choice of column, mobile phase, pH, temperature, and detector depends on the analytes and matrix. Results are compared with reference standards to assign identity and concentration. Method suitability is judged by resolution, precision, and accuracy.
HPLC testing is not a single fixed procedure; it is a family of separation modes. Reversed-phase, normal-phase, ion-exchange, size-exclusion, and affinity chromatography each suit different analyte properties. Reversed-phase methods dominate because they handle many neutral and moderately polar compounds. Detection can be optical, electrochemical, or mass spectrometric, and the detector dictates what information is available. Coupling with mass spectrometry increases selectivity and enables identification when standards are unavailable. The technique cannot separate every mixture without adjustment.
HPLC testing is an analytical technique used to separate, identify, and quantify components in a liquid sample. It relies on a pressurized mobile phase that carries the sample through a column packed with stationary phase. Different compounds travel at different rates because of interactions with the stationary and mobile phases. The resulting signal versus time is a chromatogram. Peak position indicates identity under specified conditions, while peak area or height relates to amount.
Detection in HPLC testing commonly relies on ultraviolet-visible absorbance, fluorescence, refractive index, or mass spectrometry. UV detection is widely used because many organic compounds absorb light, but it requires a chromophore. Mass spectrometry provides mass-based identification and high sensitivity for trace analytes. Each detector has trade-offs in selectivity, cost, and compatibility with mobile phases. Quantification typically uses calibration curves prepared from reference standards. Results are reported as concentration, purity, or presence above a limit.
HPLC testing separates dissolved compounds by passing a liquid sample through a column packed with stationary phase. A pump delivers mobile phase at controlled flow, and the sample components interact differently with stationary and mobile phases. Compounds that spend more time in mobile phase elute earlier; those retained by stationary phase elute later. Detectors record elution as peaks, and peak area or height relates to amount. This mechanism underpins quantitative analysis of mixtures.
| Property | Value | Notes |
|---|---|---|
| Abbreviation | HPLC | Also called high-performance liquid chromatography |
| Separation mechanism | Differential partitioning | Compounds distribute between mobile and stationary phases |
| Typical column chemistry | C18 (octadecylsilane) | Used in reversed-phase separations |
| Typical detector | UV-Vis or photodiode array | Mass spectrometry is common for trace and confirmatory work |
| Typical particle size | 1.8–5 µm | Smaller particles require higher pressure and can improve speed |
Separation in HPLC depends on the chemistry of the stationary phase, the composition of the mobile phase, and the physical properties of the column. Reverse-phase separations use a nonpolar stationary phase and a polar mobile phase, and they are common for many organic compounds. Ion-exchange, size-exclusion, and normal-phase modes serve other classes of analytes. Gradient elution changes solvent strength over time, while isocratic elution holds it constant. Flow rate, temperature, particle size, and column length all influence peak shape and resolution. Detection may use ultraviolet absorbance, fluorescence, refractive index, or mass spectrometry, depending on the analyte and the required sensitivity.
Routine HPLC testing compares a sample result with a calibration curve prepared from known reference standards. Peak area or peak height is plotted against concentration, and the curve is used to estimate unknown amounts. Retention time supports tentative identification when compared with a standard, though mass spectrometry or another confirmatory method may be needed for definitive identification. Pre-run checks verify repeatability, resolution, and peak symmetry before sample analysis. Limits of detection and quantification describe the smallest amounts that can be reliably observed or measured. Sample preparation, filtration, and degassing help prevent column damage and inconsistent results.
High-performance liquid chromatography is an analytical technique that separates components of a liquid sample by passing it through a packed column under pressure. A pump delivers a mobile phase at a controlled flow rate, and an injector introduces the sample into the stream. Differences in interaction with the stationary phase cause analytes to migrate at different rates. Detectors record elution as peaks, and a data system converts signals into a chromatogram. The method is suited to compounds that dissolve in a liquid and are not volatile enough for gas chromatography.
Reversed-phase chromatography dominates modern HPLC testing, using a nonpolar stationary phase such as chemically bonded octadecyl groups and a polar mobile phase of water mixed with organic solvent. Analytes partition between the mobile and stationary phases according to hydrophobicity. Gradient elution changes the mobile phase composition over time to separate compounds with a wide range of retention. Isocratic elution keeps the composition constant and is simpler for routine assays. Column temperature, pH, and flow rate influence selectivity, peak shape, and retention time, so these parameters are controlled during a validated method.
Routine quality control uses system suitability, blank injections, check standards, and control samples to detect drift or contamination. System suitability criteria may specify minimum resolution, maximum tailing factor, and a permitted range for repeated injections. Blank injections reveal carryover or solvent contamination, while check standards confirm calibration accuracy over a batch. Control samples with known analyte levels can show whether results remain within statistical limits. When a control result falls outside limits, the analyst investigates the cause and may invalidate affected results before repeating the batch.
Documentation and traceability are central to regulated HPLC testing. Records typically include instrument logs, column history, mobile-phase preparation, sample preparation, injection sequences, raw chromatograms, and audit trails. Electronic systems may require user access controls, time-stamped changes, and backup procedures. Training records show that analysts are qualified for assigned methods. Audits and inspections check whether written procedures match actual practice and whether deviations are documented. These controls support reproducibility and allow results to be reconstructed if questions arise later.
Method validation establishes that an HPLC procedure is suitable for its intended purpose. Typical parameters include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantitation, robustness, and solution stability. Accuracy reflects closeness to a reference value, while precision reflects agreement among repeated measurements. Specificity shows whether the method can measure the analyte without interference from matrix components. Validation is documented through protocols and reports, and the required extent depends on the method's use and regulatory context.
Routine quality control monitors retention time shifts, baseline noise, system pressure, and peak shape. Trends can reveal column aging, mobile phase preparation errors, detector drift, or sample degradation. Corrective actions may include replacing the column, preparing fresh mobile phase, or recalibrating the detector. Stability testing often uses HPLC to measure parent compound loss and degradation product formation. Open questions remain about how accelerated stability results extrapolate to long-term storage under varied conditions.
Quality control for HPLC testing combines scheduled checks, documented procedures, and review of results. Before sample analysis, system suitability testing confirms that the instrument, column, and method meet predefined criteria. Common criteria include resolution between critical peaks, retention time precision, peak tailing, and theoretical plate count. Failure triggers investigation before results are reported. Records link raw data, calculations, instrument logs, and analyst identity to each batch, supporting audits and repeat analysis.
Method validation evaluates accuracy, precision, specificity, linearity, range, detection limit, quantitation limit, and robustness. Regulatory guidance for pharmaceuticals, foods, and environmental testing defines expected documentation and acceptance criteria. Verification confirms that a validated method works in a specific laboratory with its own instruments and reagents. Calibration curves use reference standards with known purity and traceability, while measurement uncertainty is estimated from validation data, control charts, and collaborative studies. The scope of validation depends on the method's intended use.
=== Bath salts === Magnesium sulfate is used in bath salts, especially for foot baths to soothe sore feet. The reason for the inclusion of the salt is partially cosmetic: the increase in ionic strength prevents some of the temporary skin wrinkling (partial maceration) which would occur with plain water baths. Epsom salt baths have been claimed to also soothe and hasten recovery of muscle pain, soreness, or injury. However, these claims have not been scientifically confirmed. The solubility of magnesium sulfate water is inhibited by lipids in lotions resulting in variable absorption rates when applied to the skin. Temperature and concentration are also factors.
June: Jupiter IRBM deployment to Turkey begins, joining the Jupiters deployed to Italy as well as the Thor IRBMs deployed to the UK as nuclear missiles placed within striking distance of Moscow. July 11: North Korea and China sign a defensive treaty, the Sino-North Korean Mutual Aid and Cooperation Friendship Treaty. July 19: The Nicaraguan Revolution begins. August 13: The Berlin Wall is built by the Soviets following the breakdown in talks to decide the future of Germany. August 17: Alliance for Progress aid to Latin America from the United States begins. September 1: The Soviet Union resumed testing of nuclear weapons in the atmosphere. The Eritrean War of Independence begins. September 4: John F. Kennedy signs the Foreign Assistance Act. September 18: UN Secretary General Dag Hammarskjöld dies in a plane crash on his way to negotiate a ceasefire in Katanga amidst the Congo Crisis September 28: Syria withdraws from the United Arab Republic. October 17: 22nd Soviet Party Congress held in USSR. October 27: Checkpoint Charlie standoff between US and Soviet tanks begins. October 31: The Soviet Union detonates the Tsar Bomba, the most powerful thermonuclear weapon ever tested, with an explosive yield of some 50 megatons. November 18: John F. Kennedy authorizes the deployment of 18,000 military advisors to support the struggle against communist insurgents in South Vietnam. December 2: Fidel Castro openly describes himself as a Marxist–Leninist. December 18: Republic of India invades the former Portuguese territory of Goa.
=== Recipient's selection of donors === Sperm banks make information available about the sperm donors whose donations they hold to enable customers to select the donor whose sperm they wish to use. This information is often available by way of an online catalog. Subscription fees to be able to view the sperm donor through California Cryobank, for example, start at $145. Information made available by a sperm bank will usually include the race, height, weight, blood group, health and eye color of the donor. Sometimes information about the donor's age, family history and educational achievements will also be given. Some sperm banks make a 'personal profile' of a donor available and occasionally more information may be purchased about a donor, either in the form of a DVD or in written form. Catalogs usually state whether samples supplied by a particular donor have already given rise to pregnancies, but this is not necessarily a guide to the fecundity of the sperm since a donor may not have been in the program long enough for any pregnancies to have been recorded. The donor's educational qualification is also taken into account when choosing a donor.
== Clinical significance == Impaired NO production is involved in the pathogenesis of several diseases such as hypertension, preeclampsia, diabetes mellitus, obesity, erectile dysfunction, and migraine. In this regard, a large number of studies showed that polymorphisms in NOS3 gene affect the susceptibility to these diseases. Although NOS3 is a highly polymorphic gene, three genetic polymorphisms in this gene have been widely studied: the single nucleotide polymorphisms (SNPs) g.-786T>C (where "g." denotes genomic change which results in a Glu298Asp change in the coded protein), located in NOS3 promoter and in exon 7, respectively, and the variable number of tandem repeats (VNTR) characterized by 27 bp repeat in intron 4. The C allele for the g.-786T>C polymorphism, which results in reduced eNOS expression and NO production, was associated with increased risk for hypertension, preeclampsia, diabetic nephropathy, and retinopathy, migraine, and erectile dysfunction. The presence of 'Asp' allele for the Glu298Asp polymorphism reduces eNOS activity, and was associated with higher susceptibility to hypertension, preeclampsia, diabetes mellitus, migraine, and erectile dysfunction. The VNTR in intron 4 affects eNOS expression, and the susceptibility to hypertension, preeclampsia, obesity, and diabetes mellitus. Growing evidence supports the association of diseases with NOS3 haplotypes (combination of alleles in close proximity, within a DNA block). This approach may be more informative than the analysis of genetic polymorphisms one by one.
== Cap snatching and transcription in influenza == Cap snatching is best described in influenza viruses, especially influenza A. In Orthomyxoviridae, the viral family of influenza, the RdRp is divided into three subunits: PA, PB1 and PB2. PB1 first binds the 5' end of the viral RNA (vRNA), activating PB2 and causing the 3' end of the vRNA to form a double-stranded zone with the 5' end. The PB2 proceeds to bind cellular mRNA at the N7-methyl guanosine (m7G) capped 5' end. The PA subunit subsequently cleaves the sequence 10-13 nucleotides from the cap structure via endonuclease activity at the N terminus. The exact cleavage location is dependent both on the distance between the PB2 and the PA of the RdRp (around 50 angstroms or 10-13 nucleotides) and also the sequence of the mRNA. Then, the PB1 subunit, which contains the polymerase activity, initially adds on two new nucleotides. The cap snatched primer moves through the product exit tunnel in the PB1 domain to serve as the primer for transcription. The vRNA 3'-UCGUUUU nucleotides are not bound to the polymerase but rather are free for complementary binding with the capped RNA primer to confer stability. Transcription then begins with G or C residue on the 3' end of the capped primer. Finally, the PB1 subunit completes chain elongation in the canonical 5' to 3' direction, releasing the cap, but keeping the 5' end bound. The viral 3' poly-A tail is added at the end of transcription by polymerase stuttering from the steric hindrance of the vRNA loop.
Sources: en.wikipedia.org
=== Geographical territories === In the United States, the common blue violet Viola sororia is the state flower of Illinois, Rhode Island, New Jersey and Wisconsin. In Canada, the Viola cucullata is the provincial flower of New Brunswick, adopted in 1936. In the United Kingdom, Viola riviniana is the county flower of Lincolnshire.
In microfluidic Sanger sequencing the entire thermocycling amplification of DNA fragments as well as their separation by electrophoresis is done on a single glass wafer (approximately 10 cm in diameter) thus reducing the reagent usage as well as cost. In some instances researchers have shown that they can increase the throughput of conventional sequencing through the use of microchips. Research will still need to be done in order to make this use of technology effective.
* The daily recommended amounts of niacin and magnesium are higher than the tolerable upper limit because, for both nutrients, the ULs identify the amounts that will not increase the risk of adverse effects when the nutrients are consumed as a serving of a dietary supplement. Magnesium supplementation above the UL may cause diarrhea. Supplementation with niacin above the UL may cause flushing of the face and a sensation of body warmth. Each country or regional regulatory agency decides on a safety margin below when symptoms occur so that the ULs may differ based on the source. EAR U.S. Estimated Average Requirements. RDA U.S. Recommended Dietary Allowances; higher for adults than children and may be even higher for pregnant or lactating women. AI U.S. Adequate Intake; AIs are established when there is insufficient information to set EARs and RDAs. PRI Population Reference Intake is the European Union equivalent of RDA; it is higher for adults than for children and maybe even higher for pregnant or lactating women. For Thiamin and Niacin, the PRIs are expressed as amounts per megajoule (239 kilocalories) of food energy consumed. Upper Limit Tolerable upper intake levels. ND ULs have not been determined. NE EARs, PRIs, or AIs have not yet been established or will not be (EU does not consider chromium an essential nutrient).
==== The sinking of the Belgrano ==== Heseltine took a hard line on civil liberties issues. He supported Thatcher's attempt to ban trade unions from GCHQ. He supported the prosecution of Sarah Tisdall for leaking his public relations plans for the arrival of cruise missiles in 1983. Before Heseltine's arrival at the Ministry of Defence, Tam Dalyell had exposed inconsistencies in ministerial accounts of the sinking of the Argentinian warship ARA General Belgrano during the Falklands War of 1982, and alleged that the ship had been sunk to sabotage Foreign Office attempts to negotiate peace via Washington and Peru. Heseltine, apparently worried that there might be a scandal comparable to Watergate, asked Clive Ponting, a civil servant who had played an important role in Derek Rayner's efficiency reforms, to draw up a detailed report into the sinking of the Belgrano. At the end of March 1984 Ponting attended a series of meetings with Heseltine. He and the Permanent Under-Secretary Clive Whitmore wanted to disclose further information to reveal that the Belgrano had been spotted a day earlier than had previously been admitted. John Stanley, thought to be Thatcher's eyes and ears in the Ministry of Defence, initially opposed it, but Thatcher was persuaded that a letter should be sent to the Opposition Defence Spokesman Denzil Davies. However, both Heseltine and Thatcher rejected Ponting's draft which would have admitted for the first time that the Belgrano had been sighted a day earlier and stated that she was sailing away from the British taskforce when sunk.
Sources: en.wikipedia.org
, the plot would show a negative spike as temperature increases beyond the melting point, since melting is an endothermic process. Conversely, it would show a positive spike as temperature drops below the melting point. This curve can be used to calculate enthalpies of transitions. This is done by taking the time-integral of peak corresponding to a given transition:
In January 2015, Merck acquired Cubist Pharmaceuticals for $102 per share in cash or about $9.5 billion in total. In July 2015, Merck and Ablynx expanded their 18-month-old immuno-oncology collaboration by four years, generating a potential $4.4 billion in milestone payments for the Abylnx. The company also announced it would spend $95 million up front collaborating with cCAM Biotherapeutics and its early-stage treatment similar to Keytruda. Merck & Co. will bring in CM-24, an antibody designed to block the immune checkpoint CEACAM1. In January 2016, Merck announced two new partnerships; the first with Quartet Medicine and its small molecule pain treatments, the second with Complix investigating intracellular cancer targets, with both collaborations potentially generating up to $595 million and $280 million respectively. Days later the company announced it would acquire IOmet Pharma, with IOmet becoming a wholly owned subsidiary of Merck & Co. The acquisition includes IOmets indoleamine-2,3-dioxygenase 1 (IDO), tryptophan 2,3-dioxygenase (TDO), and dual-acting inhibitors. In July 2016, the company acquired Afferent Pharmaceuticals, developer of a candidate used to block P2RX3 receptors, for approximately $1 billion, plus up to $750 million in milestone payments. In 2017, Merck bought the PARP inhibitor Lynparza from AstraZeneca. In April 2017, Merck Animal Health acquired Vallée S.A., a Brazilian animal health product manufacturer.
=== Somatostatin analogs === Octreotide is an analog of the peptide hormone somatostatin, which inhibits the production of the growth hormone as well as numerous peptide hormones of the gastrointestinal system, including insulin, glucagon, pancreatic polypeptide, gastric inhibitory polypeptide, and gastrin. Octreotide is used for suppression of the hormonal syndromes which accompany several pancreatic islet cell tumors, including the Zollinger-Ellison syndrome of gastrinoma and the chronic hypoglycemia of insulinoma. It is also effective in suppression of the carcinoid syndrome, caused by advanced or extra-gastrointestinal carcinoid tumors. Octreotide may also be used for treatment of severe diarrhea caused by 5-fluorouracil chemotherapy or radiation therapy.
Sources: en.wikipedia.org
It measures the presence and amount of one or more compounds in a liquid sample. Separation occurs in a column, and detection produces a signal proportional to concentration. Identification usually requires comparison with a known reference standard under the same conditions.
In most cases the sample is consumed or altered during analysis, though some detectors are non-destructive. Fractions can be collected after separation for further study. Repeated testing therefore requires additional sample.
Run times range from under a minute for fast methods to over an hour for complex separations. Sample preparation, equilibration, and data review add time. Throughput depends on instrument configuration and method requirements.
It separates components in a liquid sample and measures their amounts using a detector. Results can indicate concentration, purity, or identity based on retention time and detector response. The technique works for mixtures that can be dissolved and filtered.